WaveSplitter | Lighting the Internet on Fiber
             

10G AOC

380 views
0 Likes
0 0
10G Base SFP+ Active Optical Cable

Share on Social Networks

Share Link

Use permanent link to share in social media

Share with a friend

Please login to send this document by email!

Embed in your website

Select page to start with

6. All contents are Copyright © 1996 – 20 1 9 Wave S plitter Technologies, Inc. All rights reserved. Preliminary and Proprietary www.wavesplitter.com Page 6 of 8 Document Number : 95 - 0164 - V 2 .0 10G SFP+ Active Optical Cable WST - SFP+AOCLCxxx M echanical drawing Unit: mm Figure1. Mechanical Specifications

3. All contents are Copyright © 1996 – 20 1 9 Wave S plitter Technologies, Inc. All rights reserved. Preliminary and Proprietary www.wavesplitter.com Page 3 of 8 Document Number : 95 - 0164 - V 2 .0 10G SFP+ Active Optical Cable WST - SFP+AOCLCxxx Pin Description SFP+ module and Host Electrical contact definition Pin No. Pin Name Function Plug Seq. Notes 1 VeeT Transmitter Ground 1 1 2 Tx_Fault Transmitter Fault Indication 3 2 3 Tx_Disable Transmitter Disable 3 3 4 SDA I2C Data Line 3 4 5 SCL I2C Clock Line 3 4 6 MOD_ABS Module Absent 3 4 7 RS0 No connection requirement 3 8 Rx_LOS Receiver Loss of Signal indication 3 5 9 RS1 Rate Select 1,control SFP+ transmitter 1 6 10 VeeR Receiver Ground 1 1 11 VeeR Receiver Ground 1 1

8. Page 8 of 8 Document Number : 95 - 0164 - V 2 .0 10G SFP+ Active Optical Cable WST - SFP+AOCLCxxx Modification History Revision Date Description Originator Review Approved V1 .0 9 - Aug - 2017 Revised Ivy Chen Min Liu Mi n Liu V2.0 6 - May - 20 19 Revised Ivy Chen Min Liu Min Li u All specification data are accurate on the date of publication for product comparisons and ordering information. WaveSp litter Technologies, Inc. reserves the right to change specifications without notice. U .S. Branch 2080 Rancho Higuera Ct. Fremont, CA 9 45 3 9, USA Tel: 510 - 651 - 7800 Fax: 510 - 651 - 7822 Taipei Headquarters 16F - 5, No.75, Sec. 1, Xintai 5th Rd., Xizhi Dist. , New Taipei C ity 221 01 , Taiwan Tel: +886 - 2 - 2 698 - 7208 Fax: +886 - 2 - 2 698 - 7210 ShenZhen Branc h 610#, 6F, No.204 Building, 2nd Industrial zone Nanyou,Nanshan district, Shenzhen, Guangdong China 518054 Tel: +86 - 755 - 86265980 Fax: +86 - 755 - 26642741

1. Data Sheet All contents are Copyright © 1996 – 20 1 9 Wave S plitter Technologies, Inc. All rights reserved. Preliminary and Proprietary www.wavesplitter.com Page 1 of 8 10G SFP+ Active Optical Cable P/N: WST - SFP+AOCLC xxx Absolute Maximum Ratings Parameter Symbol Min Max Unit Supply Voltage Vcc 0 3.6 V Storage Temperature T s - 40 +85 °C Operating Humidity - 5 85 % SFP+ AOC Specifications Parameter Description Module Form Factor SFP+ (Supports SFF 8431/SFF8432/SFF8472) Protocols Supported InfiniBand, Ethernet, Fiber Channel Channel Data Rate Rate 1 to 10.3125Gbps BER <10 - 12 Specification : ◼ 10 Gigabit Ethernet ◼ 4G and 8G Fibre Channel Applications ◼ 1x InfiniBand QDR. DDR, SDR ◼ High - performance computing clusters ◼ Serve rs, switches, storage and host card adapters Features: ◼ Electrical interface compliant to SFF - 8431 ◼ Hot Pluggable ◼ 850nm VCSEL transmitter, PIN photo - detector receiver ◼ Up to 300m on OM3 MMF ◼ Operating case temperature: 0 to 70 °C ◼ All - metal housing for superior EMI performance ◼ RoHS compliant (lead free)

7. All contents are Copyright © 1996 – 20 1 9 Wave S plitter Technologies, Inc. All rights reserved. Preliminary and Proprietary www.wavesplitter.com Page 7 of 8 Document Number : 95 - 0164 - V 2 .0 10G SFP+ Active Optical Cable WST - SFP+AOCLCxxx O rder information Part No Specification Package Datarate Fiber Cable Type Cable Length Temp . Application WST - SFP+AOCLC 012 SFP+ 10.3 Gbps OM2 LSZH PE 1m 0~70 o C 10GbE WST - SFP+AOCLC 0 3 2 SFP+ 10.3 Gbps OM2 LSZH PE 3m 0~70 o C 10GbE WST - SFP+AOCLC 0 5 2 SFP+ 10.3 Gbps OM2 LSZH PE 5m 0~70 o C 10GbE WST - SFP+AOCLC 10 2 SFP+ 10.3 Gbps OM2 LSZH PE 10m 0~70 o C 10GbE WST - SFP+AOCLC 15 2 SFP+ 10.3 Gbps OM2 LSZH PE 15m 0~70 o C 10G bE WST - SFP+AOCLC 20 2 SFP+ 10.3 Gbps OM2 LSZH PE 20m 0~70 o C 10GbE WST - SFP+AOCLC 30 2 SFP+ 10.3 Gbps OM2 LSZH PE 30m 0~70 o C 10GbE WST - SFP+AOCLC 50 2 SFP+ 10.3 Gbps OM2 LSZH PE 50m 0~70 o C 10GbE WST - SFP+AOCLC H 2 SFP+ 10.3 Gbps OM2 LSZH PE 100m 0~70 o C 10GbE Note s : 1. Cable type: LSZH 2. Fiber: OM2 or OM3 *Any special request for Cable Types (OFNR or OFNP ) , please contact our sales for detail information

2. All contents are Copyright © 1996 – 20 1 9 Wave S plitter Technologies, Inc. All rights reserved. Preliminary and Proprietary www.wavesplitter.com Page 2 of 8 Document Number : 95 - 0164 - V 2 .0 10G SFP+ Active Optical Cable WST - SFP+AOCLCxxx Operating Case Temperature 0 to + 70ºC Storage Temperature - 20 to + 85ºC Supply Voltage 3.3V Supply current 23 0mA per end typical Management Interface Serial I 2 C (Supports SFF8472) Optical characteristics The following optical characteristics are defined over the Recommended Operating Environment unless otherwise specified. Parameter Symbol Min. Typical Max Unit Notes Transmitter Center Wavelength λt 840 850 860 nm RMS spectral width Pm - - Note 1 nm Average Optical Power Pavg - 6.5 - - 1 dBm 2 Extinction Ratio ER 3.5 - - dB 3 Transmitter Dispersion Penalty TDP - - 3.9 dB Relative Intensity Noise Rin - - - 128 dB/Hz 12dB reflection Optical Ret urn Loss Tolerance - - 12 dB Receiver Center Wavelength λr 840 850 860 nm Receiver Sensitivity Psens - - - 11.1 dBm 4 Stressed Sensitivity in OMA - - - 7.5 dBm 4 Los function Los - 30 - - 12 dBm Overload Pin - - - 1.0 dBm 4 Receiver Reflectance - - - 12 dB Note s : 1. Trade - offs are available between spectral width, center wavelength and minimum OMA, as shown in table 6. 2. The optical power is launched into MMF 3. Measured with a PRBS 231 - 1 test pattern @10.3125Gbps 4.Measured with a PRBS 231 - 1 tes t pattern @10.31 25 Gbps, BER ≤ 10 - 12.

4. All contents are Copyright © 1996 – 20 1 9 Wave S plitter Technologies, Inc. All rights reserved. Preliminary and Proprietary www.wavesplitter.com Page 4 of 8 Document Number : 95 - 0164 - V 2 .0 10G SFP+ Active Optical Cable WST - SFP+AOCLCxxx 12 RD - Receiver inverted Data Output 3 13 RD+ Receiver non - inverted Data Output 3 14 VeeR Receiver Ground 1 1 15 VccR Receiver Power 2 16 VccT Transmitter Power 2 17 VeeT Transmitter Ground 1 1 18 TD+ Transmitter non - inverted Data Input 3 19 TD - Transmitter inverted Data Input 3 20 VeeT Transmitter Ground 1 1 Note s : 1. Circuit ground is internally isolated from chassis ground 2. Open - Collector outputs, asserted when LD and/or APC function fail. 3. Disable when high voltage (>2.0V or Open) 4. Should be pulled up with 4.7KΩ – 10KΩ on host board to a voltage between 2.0V and 5.5V. MOD_ABS pulls line low to indicate module is plugged in. 5. LOS is open collector output. Should be pulled up with 4.7KΩ – 10KΩ to on host board to a voltage between 2.0V and 5.5V. Logic 0 indicates normal operation; logic 1 indicates loss of signal. 6. RS1 is connected to VeeT in module. Digital Diagnostic Monitor Interface Two - wire interface ID : Data Fields – Address A 0 h Data Address Size (Bytes) Name of Field Description of Field B ASE ID FIELDS 0 1 Identifier Type of transceiver 1 1 Ext.Identifier Extended identifier of type transceiver 2 1 Connector Code for connector type 3 - 10 8 Transceiver Code for electronic compatibility or optical compatibility 11 1 Encoding Code for high speed serial encoding algorithm 12 1 BR, Nominal Nominal signaling rate, units of 100MBd. 13 1 Rate Identifier Type of rate select functionality 14 1 Length(SMF, km) Link length supported for single mode fiber, units of km 15 1 Length(SMF) Link length supported for single mode fiber, units of 100 m 16 1 Length(50um) Link length supported for 50 um OM2 fiber, units of 10 m 17 1 Length(62.5um) Link length supported for 62.5 um OM1 fiber, units of 10 m 18 1 Length(Copper) Link length supported for copp er, units of meters 19 1 Length(OM3) Link length supported for 50 um OM3 fiber, units of 10 m 20 - 35 16 Vendor name SFP vendor name (ASCII) 36 1 Unallocated

5. All contents are Copyright © 1996 – 20 1 9 Wave S plitter Technologies, Inc. All rights reserved. Preliminary and Proprietary www.wavesplitter.com Page 5 of 8 Document Number : 95 - 0164 - V 2 .0 10G SFP+ Active Optical Cable WST - SFP+AOCLCxxx 37 - 39 3 Vendor OUI SFP vendor IEEE company ID 40 - 55 16 Vendor PN Part number provided by SFP v endor (ASCII) 56 - 59 4 Vendor rev Revision level for part number provided by vendor (ASCII) 60 - 61 2 Wavelength Laser wavelength 62 1 Unallocated 63 1 CC_BASE Check code for Base ID Fields (addresses 0 to 62) EXTENDED ID FIELDS 64 - 65 2 Options Indicat es which optional transceiver signals are implemented 66 1 BR,max Upper bit rate margin, units of % 67 1 BR, min Lower bit rate margin, units of % 68 - 83 16 Vendor SN Serial number provided by vendor (ASCII) 84 - 91 8 Date code Vendor’s manufacturing date code 92 1 Diagnostic Monitoring Type Indicates which type of diagnostic monitoring is implemented(if any) in the transceiver 93 1 Enhanced Options Indicates which optional enhanced features are implemented(if any) in the transceiver 94 1 SFF - 8472 Compl iance Indicates which revision of SFF - 8472 the transceiver complieswith. 95 1 CC_EXT Check code for the Extended ID Fields (addresses 64 to 94) VENDOR SPECIFIC ID FIELDS 96 - 1 91 32 User EEPROM User writable non - volatile memory 1 92 - 255 128 Vendor Specifi c Vendor Specific EEPROM Diagnostics: Data Fields – Address A2h Data Address Size (Bytes) Name of Field Description of Field DIAGNOSTIC AND CONTROL/STATUS FIELDS BASE ID FIELDS 0 - 39 40 A/W Thresholds Diagnostic Flag Alarm and Warning Thresholds 40 - 55 1 6 Unallocated 56 - 91 36 ExtCal Constants Diagnostic calibration constants for optional External Calibration 92 - 94 3 Unallocated 95 1 CC_DMI Check code for Base Diagnostic Fields (addresses 0 to 94) 96 - 105 10 Diagnostics Diagnostic Monitor Data (intern ally or externally calibrated) 106 - 109 4 Unallocated 110 1 Status Optional Status Bits 111 1 Reserved Reserved for SFF - 8079 112 - 113 2 Alarm Flags Diagnostic Alarm Flag Status Bits 114 - 115 2 Unallocated 116 - 117 2 Warning Flags Diagnostic Warning Fla g Status Bits 118 - 119 2 Ext Status/Control Extended module control and status bytes GENERAL USE FIELDS 120 - 127 8 Vendor Specific Vendor specific memory addresses 128 - 247 120 User EEPROM User writable non - volatile memory 248 - 255 8 Vendor Control Vendo r specific control addresses

Views

  • 380 Total Views
  • 241 Website Views
  • 139 Embedded Views

Actions

  • 0 Social Shares
  • 0 Likes
  • 0 Dislikes
  • 0 Comments

Share count

  • 0 Facebook
  • 0 Twitter
  • 0 LinkedIn
  • 0 Google+

Embeds 5

  • 2 ec2.wavesplitter.com
  • 14 www.wavesplitter.com
  • 2 www.baidu.com
  • 1 18.220.135.215
  • 1 wavesplitter.com